Detection of human-induced environmental disturbances in a show cave

Año Publicación:  2011
detalles
Responsable: A. Fernandez-Cortes et al.
Journal, Volumen y páginas:
Environmental Science and Pollution Research, 18, 1037-1045

Autores

A. Fernandez-Cortes, S. Cuezva, S. Sanchez-Moral, J. C. Cañaveras, E. Porca, V. Jurado, P. M. Martin-Sanchez & C. Saiz-Jimenez

Abstract

Purpose

We investigated the effects of human-induced disruption in a subterranean stable environment containing valuable Palaeolithic paintings and engravings (Ardales Cave, Southern Spain) using a double analytical approach.

Methods

An environmental monitoring system was installed in the cave to record temperature, relative humidity, carbon dioxide (CO2) and radon (222Rn) concentrations in air. In the same stations, an aerobiological sampling was conducted to quantify the level of airborne microorganisms.

Results

The combination of different methods allowed us to detect the extent of human-induced changes, confirming that these can be very hazardous in certain cave areas that should be apparently outside the scope of human disturbances, either by their remoteness to the visitor entrance or by being briefly visited.

Conclusions

The detection of evident anomalies in the environmental parameters and airborne microorganism concentration in the cave area housing the high density of paintings and engravings helps to control human disturbances and supports the direct application of this double approach for cave management purposes.